Pages

TRZ100R-C/5P, ULTRASONIC FLOW METER FOR COMPRESSED AIR AND NITROGEN, ĐỒNG HỒ ĐO LƯU LƯỢNG KHÍ NÉN, AICHI TOKEI DENKI VIETNAM

Mã sản phẩm:
TRZ100R-C/5P
Xuất xứ:
Japan
Giá:
Liên hệ
Mô tả:




Thông tin sản phẩm

Features

A new flow meter with a new function (RS485 Output) has been added to the popular lineup of the TRX/TRZ series. It helps you save energy by measuring and “visualizing” flow rate, temperature and pressure.

Major specifications

For the specifications not described in the table, please check with the model with the relevant diameter listed in the “Detailed specifications” section above.
ModelTRX□□R-C/5PTRZ□□□R-C/5P
Diameter (Nominal diameter)25,32,40,50,65,80A100,150,200A
Power source24VDC±10% (Power consumption: 1.5 W or less)
Measurable FluidsAir (Mainly the air in a factory) or nitrogen (The configuration can be changed on-site.)Air (Mainly the air in a factory)
ConversionNormal conversionA flow rate corrected to the normal condition of 0°C and 1 atm.
Standard conversionA flow rate corrected to the standard condition of a specified temperature (configure in the flow meter) and 1 atm.
Display (when converting) *1Main display[Forward flow display mode] Accumulated flow rate: 00000000.0 (m3/h) in 9 digits Trip accumulated flow rate: 0000000.0 (m3/h) in 8 digits Instantaneous flow rate: 00000.00 (L/min) in 7 digits[Forward flow display mode] Accumulated flow rate: 0000000000 (m3/h) in 10 digits Trip accumulated flow rate: 000000000 (m3/h) in 9 digits Instantaneous flow rate: 00000.00 (L/min) in 7 digits
[Forward and reverse flow display mode] Forward accumulated flow rate: 00000000.0 (m3/h) in 9 digits Reverse accumulated flow rate: -0000000.0 (m3/h) in 8 digits Instantaneous flow rate: 00000.00 (L/min) in 7 digits[Forward and reverse flow display mode] Forward accumulated flow rate: 0000000000 (m3/h) in 10 digits Reverse accumulated flow rate: -000000000 (m3/h) in 9 digits Instantaneous flow rate: 00000.00 (L/min) in 7 digits
Sub displayInstantaneous flow rate: 0000.0 (less than 10000 m3/h) in 5 digits; 00000 (10000 m3/h or higher) in 5 digits
Pressure: 0000.0 kPa in 5 digits; Temperature: 00.0°C in 3 digits
OutputCurrent output1 system: 4 to 20 mA (±0.1mA); Load resistance: 400 Ω or less; Upper output current: 22 mA Select the output from the instantaneous flow rate, pressure and temperature by pressing a button.
Contact outputNch open-drain output 1 system: Unit pulse (Forward flow); Maximum load: 24 VDC, 50 mA
Output method: Select from Duty (35% to 65% maximum frequency: 10 Hz) or One-Shot (Select ON time from 50 ms, 100 ms, 125 ms, 250 ms and 500 ms by pressing a button).
Communication *21 system: Complies with RS 485 Modbus /RTU Communication bit rate: Select from 9600 bps, 19200 bps, 38400 bps, 57600 bps and 115200 bps by pressing a button.
*1: In the actual flow measurement setting, the digits of the accumulated flow rate display, instantaneous flow rate display and pulse output vary. *2: The communication specifications are available on our product website.

Melody

Vui lòng liên hệ Mr Nghĩa để được hỗ trợ tốt nhất!

Hotline: 0914 237 179