TRX40D-C/5P, Ultrasonic Flow Meters, Đồng hồ đo lưu lượng khí nén, Aichi Tokei Denki Vietnam



Mã sản phẩm:
TRX40D-C/5P
Xuất xứ:
Japan
Giá:
Liên hệ
Mô tả:




Thông tin sản phẩm


Features

A cost effective ultrasonic flow meter specialized for measuring air and nitrogen is now available!
It has realized a wide range of measuring ability and ZERO pressure loss using the characteristics of ultrasonic waves. It is also well-equipped to handle dust and mist and has excellent durability compared with conventional flow meters that use other measuring principles because it does not have moving parts.
The meter can be selected from two types of power sources: built-in batteries that can run 10 years without needing power construction, or an external power supply (24 VDC).
・To understand and visualize the usage of compressed air as a measure of saving electric power.. ・To understand the amount of nitrogen refined and used in a factory. (Can be applied to a degreasing treatment.)







Specifications

ModelExternal power specificationsTRX40D-C/5PTRX50D-C/5PTRX65D-C/5PTRX80D-C/5P
Built-in battery specificationsTRX40B-C/5PTRX50B-C/5PTRX65B-C/5PTRX80B-C/5P
Diameter (Nominal diameter)40A50A65A80A
Power sourceExternal power specifications24 VDC ± 10%; Power consumption: 1.1 W or less
Built-in battery specificationsLithium battery with a battery life of about 10 years (under an environmental temperature of 20°C)
Measurable fluidsAir (mainly the air in a factory) or nitrogen * Please select when ordering.
Fluid temperature and humidity– 10 to 60°C and 90% RH or less
Operating pressureLess than 0 to 1 MPa (Gauge pressure)
Flow rate range (Actual flow)±1.3~80m3/h±2.5~150m3/h±4~240m3/h±5~300m3/h
Flow measurement accuracy±2%RS±8~80m3/h±15~150m3/h±24~240m3/h±30~300m3/h
±5%RS±1.3~8m3/h±2.5~15m3/h±4~24m3/h±5~30m3/h
Low flow rate cut-off±0.2m3/h±0.4m3/h±0.5m3/h±0.8m3/h
Normal conversion accuracy± 2.5% (at 500 kPa and 25°C)
Display (Switched by buttons)ModelLCD 7 segments (with unit and alarm displays)
Main display *2[Forward flow display mode] Accumulated flow rate: 00000000.0 (Nm3/h) in 9 digits Trip accumulated flow rate: 0000000.0 (Nm3/h) in 8 digits Instantaneous flow rate: 00000.00 (NL/min) in 7 digits
[Forward and reverse flow display mode] Forward accumulated flow rate: 00000000.0 (Nm3/h) in 9 digits Reverse accumulated flow rate: -0000000.0 (Nm3/h) in 8 digits Instantaneous flow rate: 00000.00 (NL/min) in 7 digits
Sub displayInstantaneous flow rate: 000.00 (Nm 3/h, less than 200 Nm3/h) in 5 digits 0000.0 (Nm 3/h, 200 Nm3/h or more and less than 2000 Nm3/h) in 4 and 1/2 digits 00000 (Nm 3/h, 2000 Nm3/h or more) in 5 digits [200 A × 10]
Pressure: 0000.0 kPa in 5 digits Temperature: 00.0°C in 3 digits
OutputCurrent output4 to 20 mA (± 0.5% FS); Load resistance: 400 Ω or less; Upper output current: 22 mA Select output from instantaneous flow rate, pressure, and temperature by pressing a button. A separate power supply (24 VDC ± 10%) is necessary if you use the meter of the built-in battery specifications. *1
Output range (4 to 20 mA): Instantaneous flow rate 0 to ☐☐☐☐ Nm3/h (Forward flow display mode) – ☐☐☐☐ to ☐☐☐☐ Nm3/h (Forward and reverse flow display mode) ☐☐☐☐ are the values set by the button.
Pressure: 0 to 1000 kPa Temperature: -10 to 60°C
Contact outputTwo Open-drain output systems Maximum load: 24 VDC, 10 mA Maximum frequency: 10 Hz Duty: 35% to 65%
Output 1: Unit pulse (Forward flow) Output 2: Unit pulse (Reverse flow) Flow rate upper and lower limits alarm Selection of telegram output
Pulse output units: 100 NL/P or 1000 NL/P
Connection methodWafers (Fixed by JIS 10 K flanges)
Mounting positionHorizontal (LCD display to be placed upward), or vertical mounting
The materials exposed to gasesAluminum alloy, PPS, fluorosilicone rubber, etc.
MassExternal power specifications1.0kg1.2kg1.4kg1.7kg
Built-in battery specifications1.1kg1.3kg1.6kg1.8kg
Installation locationIndoor and outdoor (The safety class IP64 qualified)
Storage temperature-20 to 70°C; No condensing
Regulatory complianceCE marking compliant (EN 61000- 6-2:2005 and EN 61000- 6-4: 2007)
*1: In the actual flow measurement setting, the digits of the accumulated flow rate display, instantaneous flow rate display and pulse output vary. *2: When displaying the instantaneous flow (NL /min), the main display (accumulated flow rate), sub-display (instantaneous flow rate [Nm3/h]), pressure (kPa) and temperature (°C) will not be displayed. * Piping conditions: 20D or higher in upstream and 5D or higher in downstream for the 25A/32A models. (When using in the forward and reverse display mode, 20D or higher on both sides.) 10D or higher in upstream and 5D or higher in downstream for the 40A or larger models. (When using in the forward and reverse display mode, 10D or higher on both sides.) For more information, please contact our sales and branch offices.

Conversion chart between actual and normal flow rates

Conversion conditions40A50A65A80A
Temperature (°C)Gauge pressure (MPa)MinimumMaximumMinimumMaximumMinimumMaximumMinimumMaximum
Actual flow rate (m3/h)1.3802.515042405300
200.7(Nm3/h)9.6590181100301770372210
300.5(Nm3/h)7.043013800211280271600
0.7(Nm3/h)9.3570181070291710362140
formula