Pages

AS-W-200, ULTRASONIC FLOW METER FOR FUEL GAS, ĐỒNG HỒ ĐO LƯU LƯỢNG KHÍ GAS, AICHI TOKEI DENKI VIETNAM

Mã sản phẩm:
AS-W-200
Xuất xứ:
Japan
Giá:
Liên hệ
Mô tả:




Thông tin sản phẩm

AS-W Series

Since AS-W flow meter covers wider range from small to large flow rate, it contributes to cost saving and convenient facility management. At the same time, it saves the cost of redundant governor and piping.
・ Non-moving parts results in not degrading meter performance. It eventually makes needless to repair the parts and refuel the lubricant oil.
・ Because of the pressure loss being closely “0”, it can get rid of the pressure shortage risk.
・ Because of lightweight and compact feature, it enables easy installation and needs less space.
ModelAS-W-25AS-W-32AS-W-40AS-W-50AS-W-80AS-W-100AS-W-150AS-W-200
Nominal diameter25A32A40A50A80A100A150A200A
Power supplyBuilt-in lithium batteries
Years of duration6 years
(At surrounding temperature of 20℃)
(Exclunding 1 year of storage period)
Measurable fluidsNatural gas and air
Working pressure
(Absolute pressure)
0∼0.5MPa(AS-WW-□-500B[A/G]/3)
0∼0.2MPa(AS-WW-□-200B[A/G]/3)
0∼0.5MPa(AS-WW-□-0B[A/G]/3)
0∼1.0MPa(AS-WW-□-1000B[A/G]/3)
0∼0.5MPa(AS-WW-□-500B[A/G]/3)
0∼0.2MPa(AS-WW-□-200B[A/G]/3)
0∼1.0MPa(AS-WW-□-0B[A/G]/3)
AccuracyFlowrate measurement accuracy *1±5%RS (m³/h)Actual flow rate (m³/h)±0.7 ∼ 7±1.3 ∼ 13±1.6 ∼ 16±3 ∼ 30±6 ∼ 60±10 ∼ 100±24 ∼ 240±40 ∼ 400
±2%RS (m³/h)Actual flow rate (m³/h)±7 ∼ 35±16 ∼ 65±16 ∼ 80±30 ∼ 150±60 ∼ 300±100 ∼ 500±240 ∼ 1200±400 ∼ 2000
Low flow cut-off
(Initial flow rate) *2
Flow rate (m/s)0.05 m/s or less
Actual flow rate (m³/h)±0.1±0.2±0.2±0.4±0.8±1.5±3.2±5.7
Fluid temperature and humidity-20 to +60℃, 90% RH or less
Pressure lossZero (Equivalent to straight tube part)
DisplayAccumulated flow volumeAccumulated flow volume: 00000000.0 (9 digits/m³ or Nm³)Accumulated flow volume: 0000000000 (10 digits/m³ or Nm³)
Instantaneous flow rate *3(1) Maximum indication value: ±19999Nm³/h (converted flow rate)
(2) Maximum indication value: ±19999Nm³/h (actual flow rate)
(Two decimal places for a value less than 200, one decimal place for a value from 200 to less than 2000, integer only for a value of 2000 or more)
Temperature *300.0℃ (3-digits)
Pressure *30000.0kPa (5-digits)
OutputContact outputOpen drain output: Unit pulse (forward flow)
Pulse unit: 100,1000,10000 (L/P or NL/P)
Telegram outputRS485 Modbus/RTU
Connection methodISO7-1 Taper screw connection(JISB 0203, BS21, GB/T7306, 2-2000) equivalentISO7005-1 (GB/T9119-2002 PN1.6MPa Flange) equivalent *4
Installation positionHorizontal and vertical
Installation locationIndoor and outdoor (protection level IP 64 or equivalent)
Case materialAluminum alloyStainless alloy
The materials exposed to gasesAluminum alloy and engineering plasticStainless alloy and engineering plastic
Mass1.8kg1.7kg7.6kg9.6kg13.3kg13.2kg20.4kg35.4kg
*1. The flow rate measurement range is ±5% RS: Inclusive before “∼” and not inclusive after “∼” and ±2% RS: Inclusive for both before and after “∼”.
*2. When the flow rate is less than 0.25% of the maximum flow rate, the instantaneous flow rate is indicated as 0 m³/h. For the normal conversion type, the low flow cut off value is the normal conversion flow rate corresponding to 0.05 m/s.
*3. Automatically switched in every 4 seconds.
*4. This flowmeter guarantees the flow measurement accuracy with the pipes listed in the table below.
(If you use pipes with the different pipe standard and size not listed in the table, the flowmeter may not satisfy the flow measurement accuracy. Consult us in advance if it is considered to use different pipes out of this range.)

Pipe standardG3459 JIS 10KEN10208
Nominal diameter(mm)2532405080100150200
External diameter(mm)3442.748.35788.9108159219.1
Thickness(mm)2.82.843.54.544.510